doc patch: correct function name for slot synchronization.

Started by Hayato Kuroda (Fujitsu)over 1 year ago2 messageshackers
Jump to latest
#1Hayato Kuroda (Fujitsu)
kuroda.hayato@fujitsu.com

Dear hackers,
(CC: Amit and Shveta, who were the committer and author)

While working on the translation project of manuals, I found below sentence:

When slot synchronization is configured as recommended, and the initial
synchronization is performed either automatically or manually via
pg_sync_replication_slot, ...

However, the correct function name is pg_sync_replication_slots, and it should
be tagged as a function. Please see attached to address the issue. The typo exists
till PG17.

Best regards,
Hayato Kuroda
FUJITSU LIMITED

Attachments:

0001-doc-fix-rendering-in-logicaldecoding.sgml.patchapplication/octet-stream; name=0001-doc-fix-rendering-in-logicaldecoding.sgml.patchDownload+4-5
#2Amit Kapila
amit.kapila16@gmail.com
In reply to: Hayato Kuroda (Fujitsu) (#1)
Re: doc patch: correct function name for slot synchronization.

On Thu, Aug 21, 2025 at 2:24 PM Hayato Kuroda (Fujitsu)
<kuroda.hayato@fujitsu.com> wrote:

Dear hackers,
(CC: Amit and Shveta, who were the committer and author)

While working on the translation project of manuals, I found below sentence:

When slot synchronization is configured as recommended, and the initial
synchronization is performed either automatically or manually via
pg_sync_replication_slot, ...

However, the correct function name is pg_sync_replication_slots, and it should
be tagged as a function. Please see attached to address the issue. The typo exists
till PG17.

Thanks for noticing this and providing a patch. I'll take care of this.

--
With Regards,
Amit Kapila.